Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Metal enclosure
• Good resistance to oil and petroleum spirit
• Actuator heads can be repositioned by 4 x 90°
• 40,5 mm x 107 mm x 65,3 mm
• Actuator shaft can be turned 360°
• 1 Cable entry M 20 x 1.5

 
 
Ordering details
 
Product type descriptionTV10S 335-03Z - Ordering suffix
Article number101179253
EAN Code4030661311715
eCl@ss27-27-26-01
 
Approval
 
ApprovalBG
USA/CAN
CCC
EAC
 
Classification
 
StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)20.000.000
Mission time20 Years
notice
 
Global Properties
 
Permanent lightTV.S 335
StandardsEN 60947-5-1, BG-GS-ET-15
Compliance with the Directives (Y/N) Yes
Materials
- Material of the housingsAluminium
- Material of the contactsSilver
Housing coatingpainted
Weight253
 
Mechanical data
 
Design of electrical connectionScrew connection
Cable entry M 20 x 1.51
Cable section
- Min. Cable section0,75
- Max. Cable section2.5
Mechanical life> 1.000.000 operations
Switching frequencymax. 1000 /h
noticeAll indications about the cable section are including the conductor ferrules.
Design of actuating elementOther
Shaft boreØ 10
Positive break angle7 °
Positive break torque60 Ncm
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25 °C
- Max. environmental temperature+70 °C
Protection classIP67
 
Electrical data
 
Design of control elementOpener (NC)
Switching principleCreep circuit element
Number of auxiliary contacts0
Number of safety contacts3
Rated impulse withstand voltage Uimp6 kV
Rated insulation voltage Ui500 V
Thermal test current Ithe10 A
Utilisation categoryAC-15: 230 V / 4 A,
DC-13: 24 V / 4 A
Max. fuse rating6 A gG D-fuse
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor40.5 mm
- Height of sensor107 mm
- Length of sensor65.3 mm
 
notice
 
Setting assistanceGrub screw for location, shaft pre-drilled for pin
Universal joint available to compensate for axial displacement (only for shaft bore 10 mm)
By turning the head in 90° steps, 8 actuating planes are possible. A Torx T10 screwdriver is needed for this purpose.
Even when the screw is removed, the head is self-retaining. The switch can still not be tampered.
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact
 
Switch travel diagram
 


Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
 
Ordering suffix
 
The applicable ordering suffix is added at the end of the part number of the safety switch.
Order example: TV10S 335-03Z-NPT
...-NPT Cable entry NPT 1/2“

...-ST M12 connector with A-coding
Rated impulse withstand voltage Uimp: 0,8 kV
Rated insulation voltage Ui: 50 V
Operating current Ie: AC-15: 50 V / 4 A
Caution! The versions with connector may only be used in PELV circuits to EN 60204-1.

...-2310 M12 connector with B-coding
Rated impulse withstand voltage Uimp: 0,8 kV
Rated insulation voltage Ui: 50 V
Operating current Ie: AC-15: 50 V / 4 A
Caution! The versions with connector may only be used in PELV circuits to EN 60204-1.


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.