Notes Switch travel diagram
  Contact closed
  Contact open
  Setting range
  Break point
  Positive opening sequence/- angle
VS  adjustable range of NO contact
  adjustable range of NC contact
N   after travel
Deutsch  English  Francais  Nederlands  Italiano  Español  Português  Suomi  Svenska  Norsk  Dansk  Polska  日本語  Türkiye  中文  Português-br  
  
• Safety sensor
• Thermoplastic enclosure
• no mechanical wear
• 88 mm x 25 mm x 13 mm
• Integrated AS-Interface
• Concealed mounting possible
• Long life
• Insensitive to transverse misalignment
• Insensitive to soiling
• AS-Interface LED and status display
• 2 m Pre-wired cable with connector M12, angled, 4-pole

 
 
Ordering details
 
Product type descriptionBNS 36 STW-AS-L
Article number101194957
EAN Code4030661362212
eCl@ss27-27-24-02
 
Approval
 
Approval AS-i
USA/CAN
TÜV
 
Classification
 
StandardsEN ISO 13849-1, IEC 61508
PLup e
Control categorybis 4
PFH1.24 x 10-8 / h
- noticeup to max. 500.000 switching cycles/year
SILup 3
Mission time20 Years
 
Global Properties
 
Permanent lightBNS 36 AS
StandardsEN 50295, IEC 60947-5-3, EN ISO 13849-1, IEC 61508
Compliance with the Directives (Y/N) Yes
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
- Material of the cable mantleLSYY
Weight100
Coding available (Y/N)Yes
Response time< 100
Recommended actuatorBPS 36-1, BPS 36-2
 
Mechanical data
 
Design of electrical connectionPre-wired cable with connector M12, angled, 4-pole
Cable length2
Conductors2 x 0,23
AWG-Number23
mechanical installation conditionsquasi-flush
Ensured switch distance ON Sao7 mm
Ensured switch distance OFF Sar17 mm
Repeat accuracy R RR ≤ 0,1 x Sao
noticeAxial misalignment
The safety sensor and the actuator tolerate a horizontal and vertical misalignment to each other. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor is active in the tolerance range.
Type of actuationMagnet
Direction of motionhead-on with regard to the active surface
restistance to shock30 g / 11 ms
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
Door hingeleft
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+60
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+70
Protection classIP67 to IEC/EN 60529
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,8 kV
- Rated insulation voltage Ui32 VDC
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data - AS interface
 
AS-i Supply voltage26.5 … 31.6 VDC, Protection against polarity reversal
AS-i operating current≤ 50
AS-i Device insulationinternally short-circuit proof
AS-i Specification
- versionV 2.1
- ProfileS-0.B.F.E
- IO-Code0x0
- ID-Code0xB
- ID-Code10xF
- ID-Code20xE
AS-i Inputs
- Channel 1Data bits DI 0/DI 1= dynamic code transmission
- Channel 2Data bits DI 2/DI 3= dynamic code transmission
AS-i OutputsDO 0 … DO 3 not used
AS-i Parameter bitsP0 … P3 not used
AS-i input module address0
- Default on address 0, programmable via the AS-Interface Master or Hand-held programming device
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
AS-i LED switching conditions display
(1) green/red LED (AS-i duo LED)Supply voltage / Communication error / slave address = 0
(2) yellow LEDEnabling status
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor88
- Height of sensor25
- Length of sensor13
 
Pin assignment
 
1AS-i +
2None
3AS-i −
4None
 
Included in delivery
 
Actuators must be ordered separately.
 
Diagram
 


Note Diagram
  positive break NC contact
  active
  no active
  Normally-open contact
  Normally-closed contact

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 23.04.2019 - 20:03:42h Kasbase 3.3.0.F.64I