Ordering details |
|
Product type description | MZM 100 ST-AS MAP |
Article number | 101209554 |
EAN Code | 4030661383187 |
eCl@ss | 27-27-26-03 |
|
Approval |
|
Approval | USA/CAN |
|
Classification |
|
Standards | EN ISO 13849-1, IEC 61508, IEC 60947-5-3 |
PL | up e |
Control category | up 4 |
PFH | ≤ 5 x 10-9/h |
SIL | up 3 |
Mission time | 20 Years |
Classification | PDF-M |
|
Global Properties |
|
Permanent light | MZM 100 AS |
Standards | EN 60947-5-1, IEC 61508, EN 50295, IEC 60947-5-3, EN ISO 13849-1 |
Compliance with the Directives (Y/N)  | Yes |
Suitable for safety functions (Y/N) | Yes |
Protection rating | III |
Active principle | inductive |
Coding | Universal coding |
| low |
Duty cycle ED | 100 % |
Materials |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic |
Housing coating | None |
Weight | 628 |
Guard locking monitored (Y/N) | Yes |
Actuator monitored (Y/N) | No |
Response time | < 150 ms |
Duration of risk | < 150 ms |
Time to readiness | < 4000 |
Recommended actuator | MZM 100-B1.1 |
|
Mechanical data |
|
Design of electrical connection | connector plug M12, 4-pole |
Mechanical life | ≥ 1.000.000 operations |
notice - Mechanical life | operations for guards ≤ 5 kg; actuating speed ≤ 0,5 m/s |
restistance to shock | 30 g / 11 ms |
Resistance to vibration | 10 … 150 HZ, Amplitude 0,35 mm |
Latching (Y/N) | No |
electrically adjustable latching force | - |
Permanent magnet | 30 |
Clamping force F | 500 N |
|
Ambient conditions |
|
Ambient temperature |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +55 |
Storage and transport temperature |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +85 |
Relative humidity | 30… 95 |
- non-condensing |
- non-icing |
Protection class | IP67 to IEC/EN 60529 |
Protection rating | III |
Air clearances and creepage distances To IEC/EN 60664-1 |
- Rated impulse withstand voltage Uimp | 0,8 kV |
- Rated insulation voltage Ui | 32 VDC |
- Overvoltage category | III |
- Degree of pollution | 3 |
|
Electrical data |
|
Power to lock | Yes |
|
Electrical data - AS interface |
|
AS-i Supply voltage | 26.5 … 31.6 VDC, Protection against polarity reversal |
AS-i operating current | ≤ 100 |
AS-i Device insulation | internally short-circuit proof |
AS-i Specification |
- version | V 2.1 |
- Profile | S-7.B.F.E |
- IO-Code | 0x7 |
- ID-Code | 0xB |
- ID-Code1 | 0xF |
- ID-Code2 | 0xE |
AS-i Inputs |
- Channel 1 | Data bits DI 0/DI 1= dynamic code transmission |
- Channel 2 | Data bits DI 2/DI 3= dynamic code transmission |
AS-i Outputs |
- DO 0 | Solenoid control |
- DO 1 | not used |
- DO 2 | not used |
- DO 3 | not used |
AS-i Parameter bits |
- P0 | Actuator in |
- P1 | Solenoid interlock locked |
- P2 | Auxiliary voltage in |
- P3 | device error (Error detected) |
AS-i input module address | 0 |
- Default on address 0, programmable via the AS-Interface Master or Hand-held programming device |
|
Electrical data - Auxiliary voltage (Aux) |
|
Supply voltage UB | 24 VDC (−15 % / +10 %) stabilised PELV |
Operating current | ≤ 600 |
Device insulation | ≤ 4 A (if used in accordance with UL 508) |
|
LED switching conditions display |
|
LED switching conditions display (Y/N) | Yes |
AS-i LED switching conditions display |
(1) green/red LED (AS-i duo LED) | Supply voltage / Communication error / slave address = 0 |
(2) yellow LED | Device status |
(3) red LED | device error |
|
ATEX |
|
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
|
Dimensions |
|
Dimensions of the sensor |
- Width of sensor | 40 |
- Height of sensor | 179 |
- Length of sensor | 40 |
|
Pin assignment |
|
1 | AS-i + |
2 | Aux − (P) |
3 | AS-i − |
4 | Aux + (P) |
|
notice |
|
As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required. |
Interlocks with power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. |
|
Included in delivery |
|
Actuators must be ordered separately. |
|
Diagram |
|

Note Diagram
positive break NC contact
active
no active
Normally-open contact
Normally-closed contact |
|
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am
06.12.2019 -