Solenoid interlock  ->  AZM 200  ->  AZM 200CC-T-1P2PWA
NOTICE: Available until 2020.12.31 (substitute: AZM201)
• Thermoplastic enclosure
• Guard locking monitored
• Electronic contact-free, coded system
• Max. length of the sensor chain 200 m
• Self-monitoring series-wiring of 31 sensors
• 3 LEDs to show operating conditions
• Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
• Intelligent diagnosis
• Manual release

 
 
Ordering details
 
Product type descriptionAZM 200CC-T-1P2PWA
Article number101211074
EAN Code
eCl@ss27-27-26-03
 
Approval
 
Approval TÜV
USA/CAN
EAC
 
Classification
 
Interlocking function:
StandardsEN ISO 13849-1, IEC 61508, IEC 60947-5-3
PLbis e
Control categorybis 4
PFH4.0 x 10-9/h
PFD value1.0 x 10−4
SILbis 3
Mission time20 Years
ClassificationPDF-M
Guard locking function:
StandardsEN ISO 13849-1, IEC 61508, IEC 60947-5-3
PLup d
Control categoryup 2
PFH value2.5 x 10−9/h
PFD value2.2 x 10−4
SILup 2
Mission time20 Years
 
Global Properties
 
Permanent lightAZM 200
StandardsEN 60947-5-1, IEC 61508, EN ISO 13849-1, EN ISO 13849-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Series-wiringup to 31 components
Length of the sensor chainmax. 200 m
Active principleinductive
Duty cycle ED100 %
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Housing coatingNone
Weight537
Guard locking monitored (Y/N)Yes
Actuator monitored (Y/N)No
Idle assignable pushbutton and LED (Y/N)No
Reaction time≤ 60
Duration of risk> 120
Time to readiness4000
Recommended actuatorAZ/AZM 200-B1
 
Mechanical data
 
Design of electrical connectionSpring pulley connection
Cable section
- Min. Cable section0,25
- Max. Cable section1.5
AWG-Number23 - 15
Mechanical life≥ 1.000.000 operations
noticeAll indications about the cable section are including the conductor ferrules.
restistance to shock30 g / 11 ms
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
Emergency unlocking device (Y/N)No
Manual release (Y/N)Yes
Emergency release (Y/N)No
Latching force30
Clamping force F2000 N
Max. Actuating speed≤ 0,2
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+50
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Relative humidity30… 95
- non-condensing
Protection classIP67 to IEC/EN 60529
Protection ratingII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,8 kV
- Overvoltage categoryIII
- Degree of pollution3
 
Electrical data
 
Number of auxiliary contacts0
Number of safety contacts2
Cross circuit/short circuit recognition possible (Y/N)Yes
Power to unlockNo
Power to lockYes
Supply voltage UB
- Min. supply voltage20.4 V DC
- Max. supply voltage26.4 V DC
Switch frequency1
Rated insulation voltage Ui32 V DC
Operating current Ie1.2 A
Utilisation categoryDC-12, DC-13
No-load current I00,6 A
Device insulation≤ 4 A if used in accordance with UL 508
 
Electrical data - Safety inputs
 
Safety inputsX1 and X2
Rated operating voltage Ue- 3 V … 5 V ( Low)
15 V … 30 V ( High)
Operating current Ie> 2 mA / 24 V
 
Electrical data - Safety outputs
 
Safety outputsY1 and Y2
Fuse ratingshort-circuit proof, p-type
Rated operating voltage0 V … 4 V under Supply voltage UB
Residual current Ir≤ 0,5 mA
Operating current Ie0,25 A
Utilisation categoryDC-12, DC-13
 
Electrical data - Diagnostic output
 
Serial diagnostics (Y/N)No
Fuse ratingp-type, short-circuit proof
Operating current Ie0,05 A
Utilisation categoryDC-12, DC-13
Wiring capacitance for serial diagnostics-
diagnostic signalsguard door closed and interlocking device locked
Operating principle of the diagnostic outputThe short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC.
noticeThe diagnostic output is not a safety-relevant output!
 
Electrical data - Solenoid control IN
 
Rated operating voltage Ue- 3 V … 5 V ( Low)
15 V … 30 V ( High)
Operating current Ietypically 10 mA / 24 V, dynamically 20 mA
 
LED switching conditions display
 
LED switching conditions display (Y/N)Yes
LED switching conditions display
- Supply voltage UBgreen LED
- switching conditionyellow LED
- Error functional defectred LED
 
ATEX
 
Explosion protection categories for gasesNone
Explosion protected category for dustsNone
 
Dimensions
 
Dimensions of the sensor
- Width of sensor40
- Height of sensor220
- Length of sensor50
 
notice
 
As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required.
 
Included in delivery
 
Included in deliveryAZM 200
Triangular key
Actuators must be ordered separately.